Flux effect on void quantity and size in soldered joints
Type of document
ArticleAuthor
Bušek, D.
Dušek, K.
Růžička, D.
Plaček, M.
Mach, P.
Urbánek, J.
Starý, J.
Metadata
Show full item recordAbstract
This article is focused on both macro and microvoids in soldered joints and the use of additional flux to reduce
their frequency and minimize their negative effect on the soldered joint reliability. In total five fluxes were
used, three were gel based (NC559, MTV-125R, TSF-6516) and two of them were liquid based (Topnik G-5, JBC
FL-15). They were used within two solder pastes, both lead and lead-free. The reflow process was identical for
all of the combinations and was within the range of manufacturer recommended profiles. The amount of voids
was evaluated using X-ray analysis. It was found that the use of increased amount of proper flux, specifically
flux with higher activity, in the solder paste may significantly lower the void occurrence