dc.description.abstractMozkové metastázy jsou sekundární nádory, které se nejčastěji šíří z nádorů plic a prsu. Současné možnosti léčby zahrnují mimo jiné i stereotaxi, která je zde přínosná. Může zvýšit délku života a zmírnit komplikace spojené s růstem metastáz. Ty mohou svým růstem utlačovat přilehlé struktury a způsobovat otok mozku v okolí. Zlatým standardem pro stereotaktickou radioterapii/radiochirurgii je Leksellův gamma nůž. Ten při ozařování využívá fixní geometrie svazků se zdrojem gamma záření kobaltu 60. Další možností, jak provádět stereotaxi, je za využití lineárního urychlovače, který může být buď na robotickém rameni v případě Cyberknife, nebo součástí gantry. Klasický lineární urychlovač se pro tento účel začal využívat až později kvůli nutnosti zvýšit jeho přesnost přídavnými zařízeními. V praktické části byly porovnány v DVH křivkách u 4 pacientů kvality ozařovacích technik. Současně s tím bylo hodnoceno riziko radiotoxicity právě pro mozkový kmen. To však nebylo možné bez současného hodnocení kvality ozáření ložiska. Součástí jsou tedy i porovnané indexy pro hodnocení kvality plánů. Z dosažených hodnot by se dalo říci, že každá modalita s sebou nese určité výhody. Přestože se u LGK pokaždé dosáhlo nejlepšího dávkového spádu, s rostoucím objemem metastáz se hodnoty GI na CK a LU blížily k LGK. V případě LU bylo u 2 ze 4 případů dosaženo nejlepší konformity, ale výsledky mohly být zkresleny z důvodu nepoužití mikro MLC na LU. Na CK se dosáhlo nejhomogenějšího pokrytí. Pro vyvození závěrů nebyl vybrán dostatečný počet pacientů. Nejlepšího šetření mozkového kmene z hlediska maximální dávky na něj a doporučené objemy bylo podle výsledků dosaženo na LGK u 2 plánů ze 4. Minimálního rizika radiotoxicity bylo dosaženo u všech modalit ve všech plánech, avšak zde počet shotů, svazků, kombinace koplanárních a nekoplanárních kyvů a jejich váha mohla do jisté míry ovlivnit maximální dávku.cze
dc.description.abstractBrain metastasis are secondary tumours expanding mostly from lung and breast tumours. One of the treatment possibilities nowadays include stereotactic treatment which was found to be especially useful. It can be used to prolong the life of the patient and eliminate complications which appear as a result of the metastasis growth which causes compression to the surrounding structures and swelling in the surrounding area. The Gamma Knife is considered to be the golden standard in stereotactic radiosurgery/radiotherapy. It's using fixed geometry of beams with Cobalt 60 as source. The other option is using linear accelerator based devices on a robotic arm which is Cyberknife or as a part of gantry. The classic linear accelerator was used later because accessory equipment is needed to increase the precision. The practical part consisted of DVH graphs for the quality of these techniques in comparison. At the same time the risk of radiotoxicity was evaluated. This would not be possible without simultaneous evaluation of irradiation quality for the treated target. Therefore the quality plan metrics are also included. The final values show that each of the modalities has its advantages. Although the best dose gradient was achieved by LGK, with increasing treated volume, CK and LU were getting close to LGK performance. In 2 out of 4 patient plans, LU provided the best conformity, although the results could be possibly influenced by the usage of MLC instead of micro MLC. The CK plans had the best homogeneity, although the number of patient plans is too low to draw conclusions. The minimal maximum dose on brainstem and its recommended volumes was reached with LGK in 2 out of 4 plans. The minimum risks of radiotoxicity was reached on all modalities in all plans. The final maximum dose could be influenced by the number of shots, beams or combination of noncoplanar and coplanar arcs.eng
dc.publisherČeské vysoké učení technické v Praze. Vypočetní a informační centrum.cze
dc.publisherCzech Technical University in Prague. Computing and Information Centre.eng
dc.rightsA university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one?s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://knihovny.cvut.cz/vychova/vskp.htmleng
dc.rightsVysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://knihovny.cvut.cz/vychova/vskp.htmlcze
dc.subjectstereotaktická radiochirurgiecze
dc.subjectDVHcze
dc.subjectCKcze
dc.subjectLGKcze
dc.subjectLUcze
dc.subjectStereotactic Radiochirurgyeng
dc.subjectDVHeng
dc.subjectCKeng
dc.subjectLGKeng
dc.subjectLUeng
dc.titleDozimetrické porovnání Leksellova gamma nože, Cyberknife a Stereotaktického lineárního urychlovače v terapii pro vícečetné metastázy mozkucze
dc.titleThe Dosimetric Comparison of Leksell Gamma Knife, Cyberknife and Stereotactic Linear Accelerator for Multiple Brain Metastasiseng
dc.typebakalářská prácecze
dc.typebachelor thesiseng
dc.contributor.refereeNováková Pavla
theses.degree.disciplineRadiologický asistentcze
theses.degree.grantorkatedra zdravotnických oborů a ochrany obyvatelstvacze
theses.degree.programmeSpecializace ve zdravotnictvícze


Soubory tohoto záznamu




Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam