Model tool - Bubble CPAP



dc.contributor.advisorKudrna Petr
dc.contributor.authorDilnaz Sugralina
dc.date.accessioned2022-10-21T09:06:12Z
dc.date.available2022-10-21T09:06:12Z
dc.date.issued2022-06-13
dc.identifierKOS-1089127204805
dc.identifier.urihttp://hdl.handle.net/10467/104581
dc.description.abstractNewborn respiratory distress syndrome (NRDS) is one of the most common cause in neonatal deaths. The widely used method to solve NRDS is ventilation. Ventilation method can be 2 types: invasive and non-invasive. Invasive method is effective, however very expensive and requires trained personnel to use and maintain it. Bubble CPAP is non-invasive, simple, effective, and low-cost device. This bachelor thesis aims to develop the teaching tool bubble CPAP for demonstration in study purposes and future modification. Designed bubble CPAP is able to control the flow from flow mass controller and read the pressure oscillations. Control of flow and reading of the pressure values are performed with help of Simulink software. The work also compared the influence of the flow and depth of immersion of expiratory tube on the pressure oscillations created by bubbles in water column. Due to limitations in hardware, the designed bubble CPAP is not able correctly interpret the high-frequency pressure oscillations. Even though, the designed project is able to demonstrate main principles and patterns of the bubble CPAP.cze
dc.description.abstractNewborn respiratory distress syndrome (NRDS) is one of the most common cause in neonatal deaths. The widely used method to solve NRDS is ventilation. Ventilation method can be 2 types: invasive and non-invasive. Invasive method is effective, however very expensive and requires trained personnel to use and maintain it. Bubble CPAP is non-invasive, simple, effective, and low-cost device. This bachelor thesis aims to develop the teaching tool bubble CPAP for demonstration in study purposes and future modification. Designed bubble CPAP is able to control the flow from flow mass controller and read the pressure oscillations. Control of flow and reading of the pressure values are performed with help of Simulink software. The work also compared the influence of the flow and depth of immersion of expiratory tube on the pressure oscillations created by bubbles in water column. Due to limitations in hardware, the designed bubble CPAP is not able correctly interpret the high-frequency pressure oscillations. Even though, the designed project is able to demonstrate main principles and patterns of the bubble CPAP.eng
dc.publisherČeské vysoké učení technické v Praze. Vypočetní a informační centrum.cze
dc.publisherCzech Technical University in Prague. Computing and Information Centre.eng
dc.rightsA university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one?s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://knihovny.cvut.cz/vychova/vskp.htmleng
dc.rightsVysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://knihovny.cvut.cz/vychova/vskp.htmlcze
dc.subjectBubble CPAPcze
dc.subjectNewborn respiratory distress syndromecze
dc.subjectArduinocze
dc.subjectSimulinkcze
dc.subjectCPAPcze
dc.subjectBubble CPAPeng
dc.subjectNewborn respiratory distress syndromeeng
dc.subjectArduinoeng
dc.subjectSimulinkeng
dc.subjectCPAPeng
dc.titleModelová pomůcka - Bubble CPAPcze
dc.titleModel tool - Bubble CPAPeng
dc.typebakalářská prácecze
dc.typebachelor thesiseng
dc.contributor.refereeBláha Václav
theses.degree.disciplineBiomedicínský technikcze
theses.degree.grantorkatedra biomedicínské technikycze
theses.degree.programmeBiomedicínská a klinická technika (studium v angličtině)cze