Zobrazit minimální záznam



dc.contributor.authorAhmad I.
dc.contributor.authorFandi G.
dc.contributor.authorMüller Z.
dc.contributor.authorTlustý J.
dc.date.accessioned2019-03-27T22:33:43Z
dc.date.available2019-03-27T22:33:43Z
dc.date.issued2018
dc.identifierV3S-322613
dc.identifier.citationAHMAD, I., et al. Improvement of Voltage Profile and Mitigation of Power Losses in Case of Faults Using DG Units. In: 2018 19th International Scientific Conference on Electric Power Engineering (EPE). Brno, 2018-05-16/2018-05-18. Brno: Czech Section of the IEEE VUT, 2018. p. 85-90. ISSN 2376-5631. ISBN 978-1-5386-4612-0. DOI 10.1109/EPE.2018.8395984. Available from: https://ieeexplore.ieee.org/document/8395984
dc.identifier.isbn978-1-5386-4613-7 (print)
dc.identifier.isbn978-1-5386-4612-0 (online)
dc.identifier.issn2376-5631 (online)
dc.identifier.urihttp://hdl.handle.net/10467/81690
dc.description.abstractDistributed generation (DG) units has become an essential part of the smart grid due to increased penetration of renewable energy sources. These units help to improve power quality according to their position and control. Grids could face unexpected faults which affects power quality most especially voltage profile and power losses. This paper presents the potential application of (DG) units as a solution for improving voltage profile and mitigating power losses in loop distribution systems in case of faults for different positions of DG unit. Load flow analysis of a 66/20 kV distribution line network is performed to calculate the various values of voltage and power flow at each bus for different faults in each position of DG unit. Simulation of this distribution substation network with DG units have been developed in the MATLAB/Simulink Environment. The objective of this study is enhancement of voltage profile at various buses and the improvement in power flows in the distribution network with reduction in branch losses in the presence of fault.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherCzech Section of the IEEE VUT
dc.relation.ispartof2018 19th International Scientific Conference on Electric Power Engineering (EPE)
dc.relation.urihttps://ieeexplore.ieee.org/document/8395984
dc.subjectREACTIVE POWEReng
dc.subjectGENERATIONeng
dc.subjectFlow duration curveeng
dc.subjectRiver flow velocityeng
dc.subjectDischargeeng
dc.subjectGross powereng
dc.subjectHhaynueng
dc.subjectMbulueng
dc.titleImprovement of Voltage Profile and Mitigation of Power Losses in Case of Faults Using DG Unitseng
dc.typestať ve sborníkucze
dc.typeconference papereng
dc.identifier.doi10.1109/EPE.2018.8395984
dc.rights.accessclosedAccess
dc.identifier.wos000439649500017
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85050359447
dc.relation.conference2018 19th International Scientific Conference on Electric Power Engineering (EPE)


Soubory tohoto záznamu


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam