Zobrazit minimální záznam



dc.contributor.authorFůs M.
dc.contributor.authorPitrová Š.
dc.contributor.authorMarešová K.
dc.contributor.authorLešták J.
dc.date.accessioned2021-09-01T09:50:17Z
dc.date.available2021-09-01T09:50:17Z
dc.date.issued2021
dc.identifierV3S-350995
dc.identifier.citationFŮS, M., et al. Changes of intraocular lens position induced by Nd:YAG capsulotomy. Biomedical Papers. 2021, 2021(2021), ISSN 1804-7521. DOI 10.5507/bp.2021.014. Available from: https://biomed.papers.upol.cz/corproof.php?tartkey=bio-000000-2714
dc.identifier.issn1213-8118 (print)
dc.identifier.issn1804-7521 (online)
dc.identifier.urihttp://hdl.handle.net/10467/97053
dc.description.abstractAims. The aim of this study was to evaluate the changes in IOL position (axial shift, tilt and decentration) in the capsular bag after Nd:YAG laser capsulotomy and to create a user-friendly software that is optimized for the output of avail-able imaging technology, then verify the relationship between the biometric parameters of the eye and the extent of changes in the IOL position.Patients and Methods. The study included 35 artephakic eyes that underwent laser capsulotomy. Before and at least one hour after capsulotomy, all patients underwent the following assessments: optical biometry (Lenstar LS900), OCT with anterior segment module (Optovue Avanti) and IOL photography in infrared mode using reference unit (Verion). The original software solution was designed for the graphical evaluation of the differences between centering, axial displacement and tilt of IOL. Changes in IOL position were evaluated as simple differences before and after the laser procedure and as differences in absolute values (abs). Results. The following results show the average differences in IOL position: ACD=0.02±0.23 mm (abs=0.11±0.20 mm), IOL decentration in x-axis = -0.001±0.091 mm (abs=0.065±0.063 mm), IOL decentration in y-axis =0.012±0.119 mm (abs=0.048±0.53  mm), tilt in horizontal plane TILT-H=0.11±0.83° (abs=0.51±0.66°) and tilt in vertical plane TILT-V = -0.14±0.49° (abs=0.26±0.44°). All changes were insignificant (P>>0.05). In total, 74.29% of IOLs showed a hy-permetropic shift. A moderate positive correlation was found between the absolute differences in horizontal tilt and keratometry (r=0.45). Relationship with other changes and parameters were weak. Conclusion. In conclusion, the use of the original software solution developed by the authors showed that changes in IOL centering, axial displacement and tilt occur after Nd:YAG capsulotomy, but average differences were insignificant. In almost 3/4 cases, there was a hypermetropic axial displacement of the IOL.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherUniverzita Palackého v Olomouci
dc.relation.ispartofBiomedical Papers
dc.rightsCreative Commons Attribution (CC BY) 4.0
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectNdYAG lasereng
dc.subjectcapsulotomyeng
dc.subjectIOL positioneng
dc.subjectIOL tilteng
dc.subjectIOL centrationeng
dc.subjectIOL axial shifteng
dc.subjectposterior capsule opacificationeng
dc.titleChanges of intraocular lens position induced by Nd:YAG capsulotomyeng
dc.typečlánek v časopisecze
dc.typejournal articleeng
dc.identifier.doi10.5507/bp.2021.014
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution (CC BY) 4.0
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution (CC BY) 4.0