ČVUT DSpace
  • Search DSpace
  • Čeština
  • Login
  • Čeština
  • Čeština
View Item 
  •   ČVUT DSpace
  • Czech Technical University in Prague
  • CTU Publishing Activity
  • View Item
  • Czech Technical University in Prague
  • CTU Publishing Activity
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

FlexRay ECU mission critical parameters measurement

Type of document
článek v časopise
journal article
Peer-reviewed
acceptedVersion
Author
Sobotka J.
Novák J.



Rights
openAccess
Metadata
Show full item record
Abstract
Network operation of FlexRay Electronic Control Unit (ECU) in passenger cars is influenced by the significant number of parameters that have to be written into the ECU FlexRay controller. To keep the FlexRay network robust, the correct parameter values must be set in all ECUs of the FlexRay communication cluster. This is not a trivial task since particular ECUs are supplied by different manufacturers and any manufacturer can change some parameter either by mistake or even intentionally. The effect of such a change is generally unpredictable and can often be observed under specific operational conditions only. The most serious effect is a global FlexRay network failure, which usually leads to the fatal vehicle malfunction. Hence it was necessary to develop, implement and validate new dedicated measurement methods, enabling the evaluation of actual values of the most critical FlexRay parameters at the Open Systems Interconnection (OSI) data-link layer and thus the ECUs individual acceptances testing for system integrator verification purposes. As the mass production of FlexRay controllers is not applicable due to a lack of test specific features, deployment of these methods is enabled by utilization of unique FPGA-based FlexRay controller implementation. Proposed measurement methods are focused on parameters specifying the FlexRay wakeup protocol, FlexRay startup procedure, and the FlexRay synchronization mechanism. Each measurement method is described in detail, including its limits and prerequisites. All the developed methods were validated by experiments on real FlexRay networks and results are included in the paper. Two different types of FlexRay controller core (Freescale and Bosch E-Ray) were used in ECU under test (EUT) to eliminate the risk of measurement method dependence on a specific controller implementation.
URI
http://hdl.handle.net/10467/96383
View/Open
ACCEPTED ## OPEN (782.7Kb)
Collections
  • Publikační činnost ČVUT [1457]

České vysoké učení technické v Praze copyright © 2016 

DSpace software copyright © 2002-2016  Duraspace

Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Useful links

CTU in PragueCentral library of CTUAbout CTU Digital LibraryResourcesStudy and library skillsResearch support

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

České vysoké učení technické v Praze copyright © 2016 

DSpace software copyright © 2002-2016  Duraspace

Contact Us | Send Feedback
Theme by 
@mire NV