Zobrazit minimální záznam



dc.contributor.authorTkalenko I.
dc.contributor.authorTretyakov A.
dc.contributor.authorWald F.
dc.contributor.authorNovák J.
dc.contributor.authorŠtefan R.
dc.contributor.authorKohoutková A.
dc.date.accessioned2021-03-30T09:37:58Z
dc.date.available2021-03-30T09:37:58Z
dc.date.issued2017
dc.identifierV3S-317260
dc.identifier.citationTKALENKO, I., et al. THE STEEL AND FIBRE-REINFORCED CONCRETE CIRCULAR HOLLOW SECTION COMPOSITE COLUMN EXPOSED TO FIRE. In: Eurosteel 2017. Eurosteel 2017, Copenhagen, Copenhagen, 2017-09-13/2017-09-15. Berlin: Ernst & Sohn, 2017. p. 2678-2687. ISSN 2509-7075. DOI 10.1002/cepa.317. Available from: http://www.eurosteel2017.dk/
dc.identifier.issn2509-7075 (online)
dc.identifier.urihttp://hdl.handle.net/10467/94029
dc.description.abstractThe recent development in technology of production and transport of the steel fibre-reinforced concrete enables its utilization in composite steel-concrete structures. This work is focused on development of mechanical behaviour and design model of circular hollow section (CHS) composite steel and fibre-concrete (SFRC) column at elevated temperature. Research includes two levels accuracy/complexity, allowing simplified or advanced approach to design following the coming changes in European standard for composite member design in fire (EN1994-1-2:2005) [1]. Experimental studies of the project include mechanical tests of heated fibre-concrete samples in tension and compression, thermal behaviour under uniform and non-uniform loading of stubs of CHS and tests of full scale SFRC CHS columns in steady-state and transient-state regimes. Developing advanced finite element method (FEM) simulation of global mechanical behaviour of SFRC CHS columns is a multi-levelled composite mechanical and thermo-model and provide numerous numerical experiments. Together with standard steel material model in fire, FEM model of mechanical behaviour of fibre-reinforce concrete at elevated temperature is prepared. Validated simplified and advanced thermal model of SFRC CHS at elevated temperature gives temperature fields and moisture distribution inside section which depends on direction, heat flux, sizes and gives possibility to model different fire cases of full-scale columns in bending and buckling at elevated temperature. Prepared analytical and simplified FEM mechanical model of column is taking in account degradation of mechanical properties, analytical models of transfer of heat inside column section and provides simplified solutions for designers.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherErnst & Sohn
dc.relation.ispartofEurosteel 2017
dc.relation.urihttp://www.eurosteel2017.dk/
dc.subjectconcrete filled steel tubes (CFST)eng
dc.subjectcircular hollow section (CHS)eng
dc.subjectsteel fibro reinforced concrete (SFRC)eng
dc.subjectmechanical behavioureng
dc.titleTHE STEEL AND FIBRE-REINFORCED CONCRETE CIRCULAR HOLLOW SECTION COMPOSITE COLUMN EXPOSED TO FIREeng
dc.typestať ve sborníkucze
dc.typeconference papereng
dc.identifier.doi10.1002/cepa.317
dc.relation.projectidinfo:eu-repo/grantAgreement/Czech Science Foundation/GA/GA15-19073S/CZ/Models of steel and fibre concrete composite columns exposed to fire/SFRCCC
dc.rights.accessclosedAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion
dc.relation.conferenceEurosteel 2017, Copenhagen