Zobrazit minimální záznam



dc.contributor.authorHaller R.
dc.contributor.authorHornak J.
dc.contributor.authorTrnka P.
dc.contributor.authorHamar R.
dc.contributor.authorHlaváček J.
dc.date.accessioned2021-01-10T21:43:24Z
dc.date.available2021-01-10T21:43:24Z
dc.date.issued2020
dc.identifierV3S-345599
dc.identifier.citationHALLER, R., et al. Breakdown behaviour of oil-barrier insulation at lightning impulse voltage. In: MÜLLER, Z. and M. MÜLLER, eds. 2020 21st International Scientific Conference on Electric Power Engineering (EPE). Prague, 2020-10-19/2020-10-21. Prague: Czechoslovakia Section IEEE, 2020. ISBN 978-1-7281-9479-0. DOI 10.1109/EPE51172.2020.9269223. Available from: https://ieeexplore.ieee.org/document/9269223
dc.identifier.isbn978-1-7281-9480-6 (print)
dc.identifier.isbn978-1-7281-9479-0 (online)
dc.identifier.issn2376-5623 (print)
dc.identifier.issn2376-5631 (online)
dc.identifier.urihttp://hdl.handle.net/10467/92487
dc.description.abstractThe paper deals with some results of breakdown behavior of oil-barrier insulation at inhomogeneous field under lightning impulse voltage stress conditions. The investigation was performed with various types of mineral oil as well as natural and synthetic esters. To provide inhomogeneous field conditions a test arrangement tip-to-semi-sphere was used. For having some reference values also the same test set without barrier (pure oil) was investigated. Additionally, some tests were carried out at standardized conditions (homogeneous field). For generalizing of measured voltage values the electrical breakdown field strength was evaluated. At pure oil test set (reference values) the known polarity effect was measured, what means, that at positive polarity (tip) the breakdown values are significantly lower than at negative one. That was valid for all tested oil types excluding the synthetic ester (FR 3), at which an opposite result was obtained. With pressboard insulation the charging effect of the barrier leads to significant higher electrical breakdown field strength, dependent on used fluid. When the barrier insulation was tested with mineral oil NYTRO BIO, the highest breakdown field strength of ∼ 300 kV/mm was obtained (negative polarity). The measured polarity effect for the tested fluids was not so unambiguously as for reference values e.g. so for NYNAS TAURUS, LYRA and FR 3 lower breakdown values have been measured at negative polarity. Also the impact of surface charge on the barrier to the breakdown process was studied by simulation and measurement. Generally, the surface charge on barrier increase the resulting electrical field strength and leads in the insulating gap between barrier and semi- sphere to a (quasi) homogeneous field. The obtained results may contribute to a deeper understanding of the breakdown behavior of oil-barrier insulation at different oil/fluid types and inhomogeneous field condition.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherCzechoslovakia Section IEEE
dc.relation.ispartof2020 21st International Scientific Conference on Electric Power Engineering (EPE)
dc.subjectoil-pressboard insulationeng
dc.subjectlightning impulse breakdown voltageeng
dc.subjectelectrical breakdown field strengtheng
dc.subjectsurface chargeeng
dc.titleBreakdown behaviour of oil-barrier insulation at lightning impulse voltageeng
dc.typestať ve sborníkucze
dc.typeconference papereng
dc.identifier.doi10.1109/EPE51172.2020.9269223
dc.rights.accessclosedAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85098630243
dc.relation.conference2020 21st International Scientific Conference on Electric Power Engineering (EPE)