Zobrazit minimální záznam



dc.contributor.authorKybic, Jan
dc.contributor.authorThévenaz, Philippe
dc.contributor.authorNirkko, Arto
dc.contributor.authorUnser, Michael
dc.date.accessioned2012-02-22T13:12:47Z
dc.date.available2012-02-22T13:12:47Z
dc.date.issued2000-02
dc.identifier.citationKYBIC, J. - THEVENAZ, P. - NIRKKO, A. - UNSER, M.: Unwarping of Unidirectionally Distorted EPI Images. IEEE Transactions on Medical Imaging. 2000, vol. 19, no. 2, p. 80-93. ISSN 0278-0062. DOI: 10.1109/42.836368eng
dc.identifier.urihttp://hdl.handle.net/10467/9181
dc.description.abstractEcho-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful further processing. So far, this aspect has been too often neglected. In this paper, the authors suggest a new approach using an algorithm specifically developed for the automatic registration of distorted EPI images with corresponding anatomically correct MRI images. They model the deformation field with splines, which gives us a great deal of flexibility, while comprising the affine transform as a special case. The registration criterion is least squares. Interestingly, the complexity of its evaluation does not depend on the resolution of the control grid. The spline model gives the authors good accuracy thanks to its high approximation order. The short support of splines leads to a fast algorithm. A multiresolution approach yields robustness and additional speedup. The algorithm was tested on real as well as synthetic data, and the results were compared with a manual method. A wavelet-based Sobolev-type random deformation generator was developed for testing purposes. A blind test indicates that the proposed automatic method is faster, more reliable, and more precise than the manual one.eng
dc.language.isoengcze
dc.publisherIEEEcze
dc.rights© 2000 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.eng
dc.subjectimage registrationeng
dc.subjectsplineseng
dc.subjectgeometrical distortioneng
dc.subjectunwarpingeng
dc.titleUnwarping of Unidirectionally Distorted EPI Imagescze
dc.typečlánek z tištěného periodikacze
dc.identifier.doi10.1109/42.836368
dc.identifier.doihttp://dx.doi.org/10.1109/42.836368