Zobrazit minimální záznam



dc.contributor.authorTywoniak J.
dc.contributor.authorCalta V.
dc.contributor.authorStaněk K.
dc.contributor.authorNovák J.
dc.contributor.authorMaierová L.
dc.date.accessioned2020-02-08T18:26:24Z
dc.date.available2020-02-08T18:26:24Z
dc.date.issued2019
dc.identifierV3S-332390
dc.identifier.citationTYWONIAK, J., et al. The Application of Building Physics in the Design of Roof Windows. Energies. 2019, 12(12), ISSN 1996-1073. DOI 10.3390/en12122300. Available from: https://www.mdpi.com/1996-1073/12/12/2300
dc.identifier.issn1996-1073 (online)
dc.identifier.urihttp://hdl.handle.net/10467/86646
dc.description.abstractThis paper deals with a small but important component in a building envelope, namely roof windows in pitched roofs. Building physics methods were used to support the search for new solutions which correspond to the maximum extent for requirements for passive house level design. The first part of the paper summarizes the key phenomena of heat transfer, mainly based on a comparison of vertical windows in walls. The results of repeated two-dimensional heat transfer calculations in the form of parametric studies are presented in order to express the most important factors influencing thermal transmittance and minimum surface temperatures. Several configuration variants suitable for technical design are discussed. It was found that a combination of wood and hardened plastics in the window frame and sash is the preferred solution. The resulting thermal transmittance can be up to twice as low as usual (from 0.7 down to 0.5 W/(m(2)K), with further development ongoing. Surface temperature requirements to avoid the risk of condensation can be safely fulfilled. Concurrently, it is shown that the relative influence of thermal coupling between the window and roof construction increases with the improvement of window quality. Specific attention was given to the effect of the slanting of the side lining, which was analyzed by simulation and measurement in a daylight laboratory. The increase in thermal coupling due to slanting was found to be negligible. Motivations for specific building physics research are mentioned, such as the need to study the surface heat transfer in the case of inclined windows placed in a deep lining.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI AG)
dc.relation.ispartofEnergies
dc.relation.urihttps://www.mdpi.com/1996-1073/12/12/2300
dc.subjectroof windoweng
dc.subjectthermal performanceeng
dc.subjectpassive buildingeng
dc.subjectbuilding component developmenteng
dc.titleThe Application of Building Physics in the Design of Roof Windowseng
dc.typečlánek v časopisecze
dc.typejournal articleeng
dc.identifier.doi10.3390/en12122300
dc.relation.projectidinfo:eu-repo/grantAgreement/Ministry of Education, Youth and Sports/LO/LO1605/CZ/University centre for energy efficient buildings - sustainability phase/UCEEB++
dc.rights.accessopenAccess
dc.identifier.wos000473821400073
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion
dc.identifier.scopus2-s2.0-85068393010


Soubory tohoto záznamu


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam