Zobrazit minimální záznam



dc.contributor.authorVeselý J.
dc.contributor.authorHorný L.
dc.contributor.authorChlup H.
dc.contributor.authorAdámek T.
dc.contributor.authorKrajíček M.
dc.contributor.authorŽitný R.
dc.date.accessioned2019-03-27T22:31:20Z
dc.date.available2019-03-27T22:31:20Z
dc.date.issued2015
dc.identifierV3S-227701
dc.identifier.citationVESELÝ, J., et al. Constitutive modeling of human saphenous veins at overloading pressures. Journal of the Mechanical Behavior of Biomedical Materials. 2015, 45 101-108. ISSN 1751-6161. DOI 10.1016/j.jmbbm.2015.01.023.
dc.identifier.issn1751-6161 (print)
dc.identifier.issn1878-0180 (online)
dc.identifier.urihttp://hdl.handle.net/10467/81601
dc.description.abstractIn the present study, inflation tests with free axial extension of 15 human vena saphena magna were conducted ex vivo to obtain data suitable for multi-axial constitutive modeling at overloading conditions (pressures up to approximately 15. kPa). Subsequently the data were fitted with a hyperelastic, nonlinear and anisotropic constitutive model based on the theory of the closed thick-walled tube. It was observed that initial highly deformable behavior (up to approximately 2.5. kPa) in the pressure-circumferential stretch response is followed by progressive large strain stiffening. Contrary to that, samples were much stiffer in longitudinal direction, where the observed stretches were in the range 0.98-1.03 during the entire pressurization in most cases. The effect of possible residual stress was evaluated in a simulation of the intramural stress distribution with the opening angle prescribed to 0°, 10°, 20°, 30°, 40°, and 50°. The result suggests that the optimal opening angle making the stress distribution through the wall thickness uniform is about 40°. The material parameters presented here are suitable for use in mechanobiological simulations describing the adaptation of the autologous vein wall after bypass surgery.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherElsevier Science
dc.relation.ispartofJournal of the Mechanical Behavior of Biomedical Materials
dc.subjectAnisotropyeng
dc.subjectBypass grafteng
dc.subjectCollageneng
dc.subjectConstitutive modeleng
dc.subjectSaphenous veineng
dc.subjectStrain energy densityeng
dc.titleConstitutive modeling of human saphenous veins at overloading pressureseng
dc.typečlánek v časopisecze
dc.typejournal articleeng
dc.identifier.doi10.1016/j.jmbbm.2015.01.023
dc.relation.projectidinfo:eu-repo/grantAgreement/Ministry of Health/NT/NT13302/CZ/The Optimalization of Physical Characteristics of Vascular Substitutes for Low Flow/OptCevNah
dc.rights.accessopenAccess
dc.identifier.wos000352665100010
dc.type.statusPeer-reviewed
dc.type.versionacceptedVersion
dc.identifier.scopus2-s2.0-84923043137


Soubory tohoto záznamu


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam