Zobrazit minimální záznam



dc.contributor.authorHorný L.
dc.contributor.authorNetušil M.
dc.contributor.authorVoňavková T.
dc.date.accessioned2019-03-27T22:29:02Z
dc.date.available2019-03-27T22:29:02Z
dc.date.issued2014
dc.identifierV3S-207409
dc.identifier.citationHORNÝ, L., M. NETUŠIL, and T. VOŇAVKOVÁ. Axial prestretch and circumferential distensibility in biomechanics of abdominal aorta. Biomechanics and Modeling in Mechanobiology. 2014, 13(4), 783-799. ISSN 1617-7959. DOI 10.1007/s10237-013-0534-8.
dc.identifier.issn1617-7959 (print)
dc.identifier.issn1617-7940 (online)
dc.identifier.urihttp://hdl.handle.net/10467/81510
dc.description.abstractOur study presents the results of an analytical simulation of the inflation-extension behaviour of the human abdominal aorta treated as nonlinear, anisotropic, prestrained thin-walled as well as thick-walled tube with closed ends. The constitutive parameters and geometries for 17 aortas adopted from the literature were supplemented with initial axial prestretches obtained from the statistics of 365 autopsy measurements. For each aorta, the inflation-extension response was calculated three-times: with expected value of the initial prestretch and with the upper and lower confidence limit of the initial prestretch derived from the statistics. This approach enabled age-related trends to be evaluated bearing in mind the uncertainty in the prestretch. Despite significantly decreased longitudinal prestretch with age, the biomechanical response of human abdominal aorta changes substantially depending on the initial axial stretch used. In particular, substituting the upper limit of initial prestretch gave mechanical responses which can be characterised by (1) low variation in axial stretch, and (2) high circumferential distensibility during pressurisation, in contrast to the responses obtained for their weakly prestretched counterparts.eng
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofBiomechanics and Modeling in Mechanobiology
dc.relation.urihttp://link.springer.com/article/10.1007/s10237-013-0534-8
dc.subjectabdominal aortaeng
dc.subjectageingeng
dc.subjectconstitutive modellingeng
dc.subjectdistensibilityeng
dc.subjectelasticity tensoreng
dc.subjectresidual stress.eng
dc.titleAxial prestretch and circumferential distensibility in biomechanics of abdominal aortaeng
dc.typečlánek v časopisecze
dc.typejournal articleeng
dc.identifier.doi10.1007/s10237-013-0534-8
dc.relation.projectidinfo:eu-repo/grantAgreement/Technology Agency of the Czech Republic/TA/TA01010185/CZ/New Materials and Coatings for Joint Replacement Bionical Design/
dc.relation.projectidinfo:eu-repo/grantAgreement/Ministry of Health/NT/NT13302/CZ/The Optimalization of Physical Characteristics of Vascular Substitutes for Low Flow/OptCevNah
dc.rights.accessopenAccess
dc.identifier.wos000339156400007
dc.type.statusPeer-reviewed
dc.type.versionacceptedVersion
dc.identifier.scopus2-s2.0-84905586943


Soubory tohoto záznamu


Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam