Hledat
Zobrazují se záznamy 1-2 z 2
Effect of Particle Image Velocimetry Setting Parameters on Local Velocity Measurements in an Agitated Vessel
(VCH, 2019)
Although they are obtained under the same conditions, results on the flow field in an agitated vessel achieved using particle image velocimetry (PIV) may vary due to differences in the PIV conditions. The influence on ...
Local velocity scaling in upward flow to tooth impeller in a fully turbulent region
(EDP Sciences, 2019)
The hydrodynamics and flow field were measured in an agitated vessel using 2-D Time Resolved Particle Image Velocimetry (2-D TR PIV). The experiments were carried out in a fully baffled cylindrical flat bottom vessel 400 ...