Abstract
This paper deals with the control parameters for selected geometric accuracy measurements for a machine tool. The parameters were needed after a refurbished milling machine was purchased. After setting up the machine, it was necessary to check the geometric accuracy that can be used for precise milling. The whole check was performed in accordance with ISO 10791. Only selected parameters of geometric accuracy were inspected, and they were later compared with the prescribed values. On the basis of a comparison of these values we were able to determine whether the machine tool can be used for accurate machining.