dc.description.abstractThe underground air ducts along peripheral walls of a building are a remediation method, which principle is to enable an air flow along the moist building structure’s surface to allow a sufficient evaporation of moisture from the structure. This measure reduces the water transport (rising moisture) into the higher parts of the wall where the high water content in masonry is undesirable. Presently, underground air ducts are designed as masonry structures, which durability in contact with ground moisture is limited. The article describes a new design of an underground air duct, which is based on specially shaped concrete blocks (without wet processes, because the blocks are completely precast). The air duct from concrete blocks is situated completely below the ground surface (exterior) or below the floor (interior). Thanks to this, the system is invisible and does not disturb the authentic look of rehabilitated historic buildings. The efficiency of the air duct technical solution was verified by the results of tests (based on the measured moisture values) conducted on a laboratory model. The experimental study showed that the moisture in the masonry equipped with the presented underground air duct had decreased considerably compared to the reference sample, namely by 43 % on average. The experimental study was numerically validated through numerical simulations performed with the program WUFI 2D.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherČeské vysoké učení technické v Prazecs
dc.publisherCzech Technical University in Pragueen
dc.relation.ispartofseriesActa Polytechnica
dc.relation.urihttps://ojs.cvut.cz/ojs/index.php/ap/article/view/4160
dc.rightsCreative Commons Attribution 4.0 International Licenseen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectmoistureen
dc.subjectmasonryen
dc.subjectrefurbishmenten
dc.subjectair ductsen
dc.subjectdryingen
dc.titleUNDERGROUND AIR DUCT TO CONTROL RISING MOISTURE IN HISTORIC BUILDINGS: IMPROVED DESIGN AND ITS DRYING EFFICIENCY
dc.typearticleen
dc.date.updated2018-01-18T08:08:10Z
dc.identifier.doi10.14311/AP.2017.57.0331
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu



Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution 4.0 International License
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License