Zobrazit minimální záznam



dc.contributor.authorFořt , Jan
dc.contributor.authorBeran , Pavel
dc.contributor.authorKonvalinka , Petr
dc.contributor.authorPavlík , Zbyšek
dc.contributor.authorČerný , Robert
dc.date.accessioned2017-10-03T07:28:43Z
dc.date.available2017-10-03T07:28:43Z
dc.date.issued2017
dc.identifier.citationActa Polytechnica. 2017, vol. 57, no. 3, p. 159-166.
dc.identifier.issn1210-2709 (print)
dc.identifier.issn1805-2363 (online)
dc.identifier.urihttp://hdl.handle.net/10467/72685
dc.description.abstractThe current outdated state of many institutional and administrative buildings in the EU region poses a significant burden from the energy sustainability point of view. According to the contemporary EU requirements on the energy efficiency of buildings maintenance, an evaluation of performed improvements is essential for the assessment of expended investments. This paper describes the effect of building envelope reconstruction works consisting in the installation of a thermal insulation system. Here, a long-term continuous monitoring is used for the extensive assessment of the seasonal and daily temperature and relative humidity fluctuations. The obtained results include temperature and relative humidity profiles in the wall cross-section as a response to the changing exterior climatic conditions. The analysis of measured data reveals substantial improvements in thermal stability of the analyzed wall during temperature peaks. While the indoor temperatures exceeding 28 °C are recorded during summer before application of the thermal insulation layer, the thermal stability of the indoor environment is distinctly upgraded after performed improvements. Based on the complex long-term monitoring, a relevant experience is gained for the future work on energy sustainability and fulfilment of the EU directives.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherČeské vysoké učení technické v Prazecs
dc.publisherCzech Technical University in Pragueen
dc.relation.ispartofseriesActa Polytechnica
dc.relation.urihttps://ojs.cvut.cz/ojs/index.php/ap/article/view/4087
dc.rightsCreative Commons Attribution 4.0 International Licenseen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectin-situ monitoringen
dc.subjecttemperatureen
dc.subjectrelative humidityen
dc.subjectthermal insulationen
dc.subjectenergy sustainabilityen
dc.subjectseasonal fluctuationsen
dc.titleEVALUATION OF THE APPLICATION OF A THERMAL INSULATION SYSTEM: IN-SITU COMPARISSON OF SEASONAL AND DAILY CLIMATIC FLUCTUATIONS
dc.typearticleen
dc.date.updated2017-10-03T07:28:43Z
dc.identifier.doi10.14311/AP.2017.57.0159
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu



Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution 4.0 International License
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License