Zobrazit minimální záznam



dc.contributor.authorKracík , Petr
dc.contributor.authorPospíšil , Jiří
dc.date.accessioned2017-02-09T10:01:06Z
dc.date.available2017-02-09T10:01:06Z
dc.date.issued2015
dc.identifier.citationActa Polytechnica. 2015, vol. 55, no. 5, p. 329-334.
dc.identifier.issn1210-2709 (print)
dc.identifier.issn1805-2363 (online)
dc.identifier.urihttp://hdl.handle.net/10467/67216
dc.description.abstractWater flowing on a sprinkled tube bundle forms three basic modes: the Droplet mode (the liquid drips from one tube to another), the Jet mode (with an increasing flow rate, the droplets merge into a column) and the Membrane (Sheet) mode (with a further increase in the flow rate of the falling film liquid, the columns merge and create sheets between the tubes. With a sufficient flow rate, the sheets merge at this stage, and the tube bundle is completely covered by a thin liquid film). There are several factors influencing both the individual modes and the heat transfer. Beside the above-mentioned falling film liquid flow rate, these are for instance the tube diameters, the tube pitches in the tube bundle, or the physical conditions of the falling film liquid. This paper presents a summary of data measured at atmospheric pressure, with a tube bundle consisting of copper tubes of 12 millimetres in diameter, and with a studied tube length of one meter. The tubes are situated horizontally one above another at a pitch of 15 to 30 mm, and there is a distribution tube placed above them with water flowing through apertures of 1.0mm in diameter at a 9.2mm span. Two thermal conditions have been tested with all pitches: 15 °C to 40 °C and 15 °C to 45 °C. The temperature of the falling film liquid, which was heated during the flow through the exchanger, was 15 °C at the distribution tube input. The temperature of the heating liquid at the exchanger input, which had a constant flow rate of approx. 7.2. litres per minute, was 40 °C, or alternatively 45 °C.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherČeské vysoké učení technické v Prazecs
dc.publisherCzech Technical University in Pragueen
dc.relation.ispartofseriesActa Polytechnica
dc.relation.urihttps://ojs.cvut.cz/ojs/index.php/ap/article/view/2459
dc.rightsCreative Commons Attribution 4.0 International Licenseen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectsprinkleden
dc.subjecttube bundleen
dc.subjectheat transferen
dc.subjecttube pitchen
dc.titleEFFECT OF TUBE PITCH ON HEAR TRANSFER IN SPRINKLED TUBE BUNDLE
dc.typearticleen
dc.date.updated2017-02-09T10:01:06Z
dc.identifier.doi10.14311/AP.2015.55.0329
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu



Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution 4.0 International License
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License