Design of the testing procedure for investigation of Eryx conicus dermal armour characteristics
dc.contributor.author | Žaloudková, Blanka | |
dc.contributor.author | Koudelka, Petr | |
dc.contributor.author | Frýdlová, Petra | |
dc.contributor.author | Drozdenko, Mykhailo | |
dc.contributor.author | Šleichrt, Jan | |
dc.contributor.author | Kytýř, Daniel | |
dc.date.accessioned | 2024-11-21T09:03:09Z | |
dc.date.available | 2024-11-21T09:03:09Z | |
dc.date.issued | 2024 | |
dc.identifier.citation | Acta Polytechnica. 2024, vol. 48, no. , p. 61-65. | |
dc.identifier.issn | 1210-2709 (print) | |
dc.identifier.issn | 1805-2363 (online) | |
dc.identifier.uri | http://hdl.handle.net/10467/119446 | |
dc.description.abstract | The aim of this work is to develop an experimental method suitable for the mechanical testing of highly non-standard biological samples such as snake skin with osteoderms. The objective of the method is to determine, whether the osteoderms provide a protective function for the animal in its natural environment. For this purpose, a simulation of rodents biting the skin based on uni-axial compressive loading using a synthetic tooth as a penetrator was developed with an emphasis on integration with X-ray scanners to facilitate in-situ testing. To identify and characterise the structure of snake skin and to prove the protective function of osteoderms, all samples were subjected to high resolution X-ray computed tomography. The results of the experiments are presented in the form of stress-strain curves and a map of the tangent modulus. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | České vysoké učení technické v Praze | cs |
dc.publisher | Czech Technical University in Prague | en |
dc.relation.ispartofseries | Acta Polytechnica | |
dc.relation.uri | https://ojs.cvut.cz/ojs/index.php/APP/article/view/10119 | |
dc.rights | Creative Commons Attribution 4.0 International License | en |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.title | Design of the testing procedure for investigation of Eryx conicus dermal armour characteristics | |
dc.type | article | en |
dc.date.updated | 2024-11-21T09:03:09Z | |
dc.rights.access | openAccess | |
dc.type.status | Peer-reviewed | |
dc.type.version | publishedVersion |