Zobrazit minimální záznam



dc.contributor.authorBelynda, Fares
dc.contributor.authorAbdelli, Radia
dc.contributor.authorBouzida, Ahcene
dc.date.accessioned2023-11-24T10:24:12Z
dc.date.available2023-11-24T10:24:12Z
dc.date.issued2023
dc.identifier.citationActa Polytechnica. 2023, vol. 63, no. 5, p. 293–304.
dc.identifier.issn1210-2709 (print)
dc.identifier.issn1805-2363 (online)
dc.identifier.urihttp://hdl.handle.net/10467/112920
dc.description.abstractThis paper presents a novel method for modelling and diagnosis of electrical and mechanical faults in fixed-Speed Self-Excited Induction Generators (SEIGs) operating in autonomous mode in a small-scale wind energy system. The proposed method is validated using the finite element method. After the selection of the magnetising capacitors, the self-excitation process is performed under no-load conditions. Once the stator voltage is established, a symmetrical three-phase load is connected. The fault detection method introduced here is called Stator Current Signal Crossing (SCSC). The SCSC extracts a new signal from the stator currents, that enables the detection of stator inter turn shortcircuits, broken rotor bars, and dynamic eccentricity faults in SEIGs. A spectral analysis of SCSC using the Fast Fourier Transform (FFT) algorithm is used to precisely locate the induced fault components. What sets this fault-tracking method apart from its predecessors is its exceptional ability to detect faults of any magnitude by analysing the modulation of the SCSC signal. These faults are directly identified by the presence of distinct harmonics, each indicative of a specific type of fault. This study also focuses on the SEIG in a wind energy system, whereas previous works have mainly addressed the induction machine in motor mode. In contrast, previous methods involved analysing a single current signal and isolating specific harmonics from a wide frequency range. The effectiveness of the proposed fault detection method and the self-excitation process are illustrated by simulation results and spectral analysis.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherČeské vysoké učení technické v Prazecs
dc.publisherCzech Technical University in Pragueen
dc.relation.ispartofseriesActa Polytechnica
dc.relation.urihttps://ojs.cvut.cz/ojs/index.php/ap/article/view/8463
dc.rightsCreative Commons Attribution 4.0 International Licenseen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleStator current signal crossing for fault diagnosis of self-excited induction generators
dc.typearticleen
dc.date.updated2023-11-24T10:24:12Z
dc.identifier.doi10.14311/AP.2023.63.0293
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu



Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution 4.0 International License
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License