Zobrazit minimální záznam



dc.contributor.authorAl-Awad, Nasir Ahmed
dc.contributor.authorHumaidi, Amjad Jaleel
dc.contributor.authorAl-Araji, Ahmed Sabah
dc.date.accessioned2023-09-19T11:15:27Z
dc.date.available2023-09-19T11:15:27Z
dc.date.issued2023
dc.identifier.citationActa Polytechnica. 2023, vol. 63, no. 3, p. 158–170.
dc.identifier.issn1210-2709 (print)
dc.identifier.issn1805-2363 (online)
dc.identifier.urihttp://hdl.handle.net/10467/111906
dc.description.abstractRehabilitation Exoskeleton is becoming more and more important in physiotherapists’ routine work. To improve the treatment performance, such as reducing the recovery period and/or monitoring and reacting to unpredictable situations, the rehabilitation manipulators need to help the patients in various physical trainings. A special case of the active disturbance rejection control (ADRC) is applied to govern a proper realisation of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behaviour resembles a real exoskeleton rehabilitation device (a one-degree-of-freedom, rigid-link, flexible-joint manipulator). The fractional (FADRC) is an unconventional model-independent approach, acknowledged as an effective controller in the existence of total plant uncertainties, and these uncertainties are inclusive of the total disturbances and unknown dynamics of the plant. In this work, three FADRC schemes are used, the first one using a fractional state observer (FSO), or FADRC1, second one using a fractional proportional-derivative controller (FPD), or FADRC2, and the third one a Multi-loop fractional in PD-loop controller and the observer-loop (Feedforward and Feedback), or FADRC3. The simulated Exoskeleton system is subjected to a noise disturbance and the FADRC3 shows the effectiveness to compensate all these effects and satisfies the desired position when compared with FADRC1 and FADRC2. The design and simulation were carried out in MATLAB/Simulink.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherČeské vysoké učení technické v Prazecs
dc.publisherCzech Technical University in Pragueen
dc.relation.ispartofseriesActa Polytechnica
dc.relation.urihttps://ojs.cvut.cz/ojs/index.php/ap/article/view/8631
dc.rightsCreative Commons Attribution 4.0 International Licenseen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleFractional multi-loop active disturbance rejection control for a lower knee exoskeleton system
dc.typearticleen
dc.date.updated2023-09-19T11:15:27Z
dc.identifier.doi10.14311/AP.2023.63.0158
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu



Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution 4.0 International License
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License