Zobrazit minimální záznam



dc.contributor.authorRoyaei, Javad
dc.contributor.authorSadeghi, Kabir
dc.contributor.authorNouban, Fatemeh
dc.date.accessioned2023-09-19T11:15:24Z
dc.date.available2023-09-19T11:15:24Z
dc.date.issued2023
dc.identifier.citationActa Polytechnica. 2023, vol. 63, no. 3, p. 208–215.
dc.identifier.issn1210-2709 (print)
dc.identifier.issn1805-2363 (online)
dc.identifier.urihttp://hdl.handle.net/10467/111905
dc.description.abstractIn this paper, a 28-day compressive strength test has been performed on samples including normal fibre concrete and high-strength concrete. The ultrasonic test (UT) as a non-destructive and compression machine (CM) as a destructive test were applied, and the results were compared. To investigate the effect of temperature, the samples were subjected to 200, 400, 600, 800, 1000, and 1200 degrees Celsius and the exposure time was equal to 30, 45, 60, 90, 120, and 180 minutes. Based on the results, it was observed that the minimum error observed between the UT and CM tests was 2.9 % and the maximum error between the two methods was 10.9 %, which shows the high accuracy of the ultrasonic testing method in determining the specimen’s strength. The average probable error of the method is determined to be around 6.8 %.Based on the results of the average decrease in compressive strength versus the heat exposure time, it is observed that the trend of changes and decrease in resistance over time for both types of tests is almost the same and has a negligible difference. At the end of 180 minutes of exposure, the resistance ratio for the ultrasonic test is 69.8 %, and 71.1 % for the compression machine. Furthermore, according to the average reduction in compressive strength due to heat exposure time, it has been observed that the results of the UT and UM tests have slight numerical differences, however, the trend of changes and reduction in resistance over time for both types of tests is almost the same. Finally, the accuracy of the UT in determining the compressive strength of specimens at high temperatures is fully confirmed.en
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherČeské vysoké učení technické v Prazecs
dc.publisherCzech Technical University in Pragueen
dc.relation.ispartofseriesActa Polytechnica
dc.relation.urihttps://ojs.cvut.cz/ojs/index.php/ap/article/view/8612
dc.rightsCreative Commons Attribution 4.0 International Licenseen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleA comparative experimental investigation of high-temperature effect on fibre concrete and high strength concrete using UT and CM methods
dc.typearticleen
dc.date.updated2023-09-19T11:15:24Z
dc.identifier.doi10.14311/AP.2023.63.0208
dc.rights.accessopenAccess
dc.type.statusPeer-reviewed
dc.type.versionpublishedVersion


Soubory tohoto záznamu



Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam

Creative Commons Attribution 4.0 International License
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License