DIAMOND DETECTORS FOR FAST TRANSIENT SCRAM MEASUREMENTS – THE DETECTOR DEVELOPMENT
Type of document
articlePeer-reviewed
publishedVersion
Author
Novák, Ondřej
Sklenka, Lubomír
Pomorski, Michal
Lynde, Clement
Rights
Creative Commons Attribution 4.0 International Licensehttp://creativecommons.org/licenses/by/4.0/
openAccess
Metadata
Show full item recordAbstract
This paper presents a development of special diamond detector for time dependent neutron flux measurements in a nuclear reactor. Neutron flux changes during SCRAM are difficult to measure by existing detector technologies. Therefore, a new detector is developed. This new type diamond based detector should allow to perform fast measurements of neutron flux during SCRAM with high pulse count rate. The diamond detector design and signal processing are described in this paper including the pulse shape discrimination method. In addition to theoretical detector study, three detector was manufactured at CEA Saclay. Experience gathered during manufacturing is described as well.
Collections
The following license files are associated with this item:
Except where otherwise noted, this item's license is described as Creative Commons Attribution 4.0 International License