INFLUENCE OF PRINTING AND LOADING DIRECTION ON MECHANICAL RESPONSE IN 3D PRINTED MODELS OF HUMAN TRABECULAR BONE
dc.contributor.author | Doktor, Tomáš | |
dc.contributor.author | Kumpová, Ivana | |
dc.contributor.author | Wroński, Sebastian | |
dc.contributor.author | Śniechowski, Maciej | |
dc.contributor.author | Tarasiuk, Jacek | |
dc.contributor.author | Forte, Giancarlo | |
dc.contributor.author | Kytýř, Daniel | |
dc.date.accessioned | 2023-01-18T15:14:34Z | |
dc.date.available | 2023-01-18T15:14:34Z | |
dc.date.issued | 2018 | |
dc.identifier.citation | Acta Polytechnica. 2018, vol. 18, no. 0, p. 24-27. | |
dc.identifier.issn | 1210-2709 (print) | |
dc.identifier.issn | 1805-2363 (online) | |
dc.identifier.uri | http://hdl.handle.net/10467/106048 | |
dc.description.abstract | The paper deals with investigation on directional variations of mechanical response in 3D printed models of human trabecular bone. Sample of trabecular bone tissue was resected from human donor and 3D model was obtained by X-ray computed tomography. Then a series of cubical samples was prepared by additive manufacturing technique and tested by uniaxial compression loading mode. Mechanical response was compared in nine different combinations of direction of 3D printing and loading direction. The results show neglectible influence on the deformation response in elastic region (stiffness) and significant changes of the behaviour in plastic region (stress and strain at yield point, strain at full collapse). | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | České vysoké učení technické v Praze | cs |
dc.publisher | Czech Technical University in Prague | en |
dc.relation.ispartofseries | Acta Polytechnica | |
dc.relation.uri | https://ojs.cvut.cz/ojs/index.php/APP/article/view/5082 | |
dc.rights | Creative Commons Attribution 4.0 International License | en |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.title | INFLUENCE OF PRINTING AND LOADING DIRECTION ON MECHANICAL RESPONSE IN 3D PRINTED MODELS OF HUMAN TRABECULAR BONE | |
dc.type | article | en |
dc.date.updated | 2023-01-18T15:14:34Z | |
dc.identifier.doi | 10.14311/APP.2018.18.0024 | |
dc.rights.access | openAccess | |
dc.type.status | Peer-reviewed | |
dc.type.version | publishedVersion |
Soubory tohoto záznamu
Tento záznam se objevuje v následujících kolekcích
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License