SEMI–AUTOMATED ASSESSMENT OF MICROMECHANICAL PROPERTIES OF THE METAL FOAMS ON THE CELL-WALL LEVEL
Type of document
articlePeer-reviewed
publishedVersion
Author
Krčmářová, Nela
Šleichrt, Jan
Doktor, Tomáš
Kytýř, Daniel
Jiroušek, Ondřej
Rights
Creative Commons Attribution 4.0 International Licensehttp://creativecommons.org/licenses/by/4.0/
openAccess
Metadata
Show full item recordAbstract
Metal foams are innovative porous material used for wide range of application such as deformation energy or sound absorption, filter material, or microbiological incubation carrier. To predict mechanical properties of the metal foam is necessary to precisely describe elasto–plastic properties of the foam on cell–wall level. Indentation with low load is suitable tool for this purpose. In this paper custom designed instrumented microindentation device was used for measurement of cell-wall characteristics of two different aluminium foams (ALPORAS and ALCORAS). To demonstrate the possibility of automated statistical estimation of measured characteristics the device had been enhanced by semi-automatic indent positioning and evaluation procedures based on user-defined grid. Vickers hardness was measured on two samples made from ALPORAS aluminium foam and one sample from ALCORAS aluminium foam. Average Vickers hardness of ALPORAS foam was 24.465HV1.019 and average Vickers hardness of ALCORAS was 36.585HV1.019.