QUENCH FRONT PROPAGATION IN THE ANNULAR CHANNEL
Typ dokumentu
articlePeer-reviewed
publishedVersion
Autor
Stepanek, Jan
Blaha, Vaclav
Dostal, Vaclav
Práva
Creative Commons Attribution 4.0 International Licensehttp://creativecommons.org/licenses/by/4.0/
openAccess
Metadata
Zobrazit celý záznamAbstrakt
Understanding the quench front propagation during bottom core reflooding is crucial for the effective cooling during the LOCA accident. The results presented in this paper were obtained on an experimental loop with an annular test section. The test section consists of a vertical electrically heated stainless steel tube with outer diameter 9 mm and length of 1.7 m. The heated tube is placed inside a glass tube with the inner diameter 14.5 mm. Water mass flux during the reflooding is in the range from 100 kg.m−2.s−1 up to 140 kg.m−2.s−1 and the initial wall temperature of the stainless steel tube is in the range from 250 °C up to 800 °C. The presented results show the influence of the initial conditions on the quench front propagation and the complexity of the phenomenon.
Kolekce
K tomuto záznamu jsou přiřazeny následující licenční soubory:
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License