MULTI-CHANNEL CONTROL SYSTEM FOR IN-SITU LABORATORY LOADING DEVICES
(České vysoké učení technické v PrazeCzech Technical University in Prague, 2018)
In recent years, open-source applications have replaced proprietary software in many fields. Especially open-source software tools based on Linux operating system have wide range of utilization. In terms of CNC solutions, ...
INSTRUMENTATION OF SPLIT HOPKINSON PRESSURE BAR FOR TESTING OF CELLULAR METALLIC MATERIALS
(České vysoké učení technické v PrazeCzech Technical University in Prague, 2018)
This paper presents an overview of the custom design instrumentation of a Split Hopkinson Pressure Bar modified for dynamic testing of materials with low mechanical impedance, particularly for cellular metallic materials ...
CHARACTERIZATION OF THE FRACTURE MECHANICAL BEHAVIOR OF C-SMC MATERIALS
(České vysoké učení technické v PrazeCzech Technical University in Prague, 2018)
The fracture mechanics of random discontinuous Carbon Fiber Sheet Molding Compound (C-SMC) materials compared to traditional carbon fiber composites are not well understood. An experimental study was carried out to ...
OPTIMIZATION OF DECOMPRESSIVE CRANIECTOMY BASED ON FINITE ELEMENT SIMULATIONS
(České vysoké učení technické v PrazeCzech Technical University in Prague, 2018)
Decompressive Craniectomy (DC) is a neurosurgical procedure which is often applied to decrease the intracranial pressure (ICP), even if its optimal execution in terms of the size and location of the skull opening is not ...
PREPROCESSING OF HOPKINSON BAR EXPERIMENT DATA: FILTER ANALYSIS
(České vysoké učení technické v PrazeCzech Technical University in Prague, 2018)
This work presents a data preprocessing procedure for signal acquired during high strain-rate loading using a custom Split Hopkinson Pressure Bar (SHPB). Before the evaluation of the experimental data, preprocessing of the ...
EXPERIMENTAL INVESTIGATION OF THE FAILURE BEHAVIOUR OF POLYPROPYLENE COMPOUNDS FOR INSTRUMENTED PUNCTURE TESTS
(České vysoké učení technické v PrazeCzech Technical University in Prague, 2018)
Instrumented puncture tests according to ISO 6603-2 and ASTMD3763 were executed for five different Polypropylene compounds (talcum-, glass fibre- and elastomer modified) with specimen thicknesses ranging from 1mm to 4 mm. ...