Disinfection performance of an ultraviolet lamp: a CFD investigation
Typ dokumentu
articlePeer-reviewed
publishedVersion
Autor
Bui, Cuong Mai
Phan, Nguyen Duy Minh
Tran, Ngo Quoc Huy
Doan, Le Anh
Vo, Quang Truong
Tran, Duy Chung
Nguyen, Thi Thanh Vi
Nguyen, Duc Long
Huynh, Van Sanh
Ho, Tran Anh Ngoc
Práva
Creative Commons Attribution 4.0 International Licensehttp://creativecommons.org/licenses/by/4.0/
openAccess
Metadata
Zobrazit celý záznamAbstrakt
Ultraviolet (UV)-based devices have shown their effectiveness on various germicidal purposes. To serve their design optimisation, the disinfection effectiveness of a vertically cylindrical UV lamp, whose wattage ranges from P = 30 − 100 W, is numerically investigated in this work. The UV radiation is solved by the Finite Volume Method together with the Discrete Ordinates model. Various results for the UV intensity and its bactericidal effects against several popular virus types, i.e., Corona-SARS, Herpes (type 2), and HIV, are reported and analysed in detail. Results show that the UV irradiance is greatly dependent on the lamp power. Additionally, it is indicated that the higher the lamp wattage employed, the larger the bactericidal rate is observed, resulting in the greater effectiveness of the UV disinfection process. Nevertheless, the wattage of P ≤ 100W is determined to be insufficient for an effective disinfection performance in a whole room; higher values of power must hence be considered in case intensive sterilization is required. Furthermore, the germicidal effect gets reduced with the viruses less sensitive to UV rays, e.g, the bactericidal rate against the HIV virus is only ∼8.98% at the surrounding walls.
Kolekce
K tomuto záznamu jsou přiřazeny následující licenční soubory:
Kromě případů, kde je uvedeno jinak, licence tohoto záznamu je Creative Commons Attribution 4.0 International License