Rheology of collagen material

Supervisors

Reviewers

Editors

Other contributors

Journal Title

Journal ISSN

Volume Title

Publisher

České vysoké učení technické v Praze
Czech Technical University in Prague

Date of defense

Research Projects

Organizational Units

Journal Issue

Abstract

The thesis deals with the investigation of the flow behaviour of collagen material. Literature search focused on collagen material description, the flow behaviour of collagen, experimental techniques to obtain information about flow behaviour of collagen material and theoretical approaches to explain and describe of the flow of material similar to collagen. From the literature search, the best device for measurement collagen material in the form of dough is slit rheometer. There are lack information about rheology of collagen material. Pure viscous power-law model or Herschel-Bulkley model are used for the flow description of collagen material. The experiment results from literature were used for the rheology of collagen investigation. Measurements were performed on slit rheometer with three different capillaries. Slits have a rectangular shape with constant width and various thickness of 2, 4 and 8 mm. This thesis uses regression analysis done on the slit rheometer with different heights. The power-law model and Herschel-Bulkley model are applied after regression analysis. Data is obtained from 5 different pressure transducers and evaluated in my own script in MATLAB. The exit pressure relation for slit rheometer is also covered in this work.

The thesis deals with the investigation of the flow behaviour of collagen material. Literature search focused on collagen material description, the flow behaviour of collagen, experimental techniques to obtain information about flow behaviour of collagen material and theoretical approaches to explain and describe of the flow of material similar to collagen. From the literature search, the best device for measurement collagen material in the form of dough is slit rheometer. There are lack information about rheology of collagen material. Pure viscous power-law model or Herschel-Bulkley model are used for the flow description of collagen material. The experiment results from literature were used for the rheology of collagen investigation. Measurements were performed on slit rheometer with three different capillaries. Slits have a rectangular shape with constant width and various thickness of 2, 4 and 8 mm. This thesis uses regression analysis done on the slit rheometer with different heights. The power-law model and Herschel-Bulkley model are applied after regression analysis. Data is obtained from 5 different pressure transducers and evaluated in my own script in MATLAB. The exit pressure relation for slit rheometer is also covered in this work.

Description

Citation

Underlying research data set URL

Rights/License

A university thesis is a work protected by the Copyright Act of the Czech Republic. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one`s own expense. The use of thesis should be in compliance with the Copyright Act.

Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem v platném znění.

Endorsement

Review

Supplemented By

Referenced By