Effects of Core Dimensions and Manufacturing Procedure on Fluxgate Noise
| dc.contributor.author | Janošek M. | |
| dc.contributor.author | Vyhnánek J. | |
| dc.contributor.author | Zikmund A. | |
| dc.contributor.author | Butvin P. | |
| dc.contributor.author | Butvinová B. | |
| dc.date.accessioned | 2019-03-27T22:29:23Z | |
| dc.date.available | 2019-03-27T22:29:23Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | The effect of demagnetizing factor and manufacturing procedure on noise of the fluxgate probes, manufactured from metallic glasses, is presented. The fluxgate probes were either tape-wound, or flat, wet-etched ringcore and race-track geometries. When combining low demagnetizing factor and high enough cross-section of the probe, a minimum in the noise dependence can be found. For 50 mm ringcores, in such minimum the noise value as low as 7 pTRMS in 0.1-10 Hz frequency band was achieved, which is very low for an as-cast tape, and has not been reported before. | |
| dc.identifier | V3S-218168 | |
| dc.identifier.citation | JANOŠEK, M., et al. Effects of Core Dimensions and Manufacturing Procedure on Fluxgate Noise. Acta Physica Polonica A. 2014, 126(1), 104-105. ISSN 0587-4246. DOI 10.12693/APhysPolA.126.104. | |
| dc.identifier.doi | 10.12693/APhysPolA.126.104 | |
| dc.identifier.issn | 0587-4246 (print) | |
| dc.identifier.issn | 1898-794X (online) | |
| dc.identifier.scopus | 2-s2.0-84902197625 | |
| dc.identifier.uri | http://hdl.handle.net/10467/81524 | |
| dc.identifier.wos | 000339833100049 | |
| dc.language.iso | eng | |
| dc.publisher | Polish Academy of Sciences | |
| dc.relation.ispartof | Acta Physica Polonica A | |
| dc.relation.projectid | info:eu-repo/grantAgreement/Czech Science Foundation/GA/GAP102%2F12%2F2177/CZ/Nanostructured soft magnetic materials for sensors/ | |
| dc.relation.projectid | info:eu-repo/grantAgreement/Ministry of Education, Youth and Sports/7A/7AMB12SK027/CZ/Metallic ribbons for magnetic sensors/MERIMAS | |
| dc.relation.uri | http://przyrbwn.icm.edu.pl/APP/PDF/126/a126z1p048.pdf | |
| dc.rights.access | openAccess | |
| dc.subject | fluxgate | en |
| dc.subject | noise | en |
| dc.subject | demagnetizing | en |
| dc.title | Effects of Core Dimensions and Manufacturing Procedure on Fluxgate Noise | |
| dc.type | journal article | en |
| dc.type.status | Peer-reviewed | |
| dc.type.version | submittedVersion | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 37e43c80-90f1-4717-b70d-99879d3b4a78 | |
| relation.isAuthorOfPublication | d33fb86f-43cc-4063-ab6a-bcd88161bcc0 | |
| relation.isAuthorOfPublication | bd851fe1-7c95-4190-84fb-72ce83edbc90 | |
| relation.isAuthorOfPublication.latestForDiscovery | 37e43c80-90f1-4717-b70d-99879d3b4a78 |
Files
Original bundle
1 - 1 of 1
- Name:
- Janosek_Vyhnanek_Zikmund_et_al__Effects_of_Core_Dimensions_and_Manufacturing_Procedure_on_Fluxgate_Noise__(2014)_SUBV_218168.pdf
- Size:
- 650.45 KB
- Format:
- Adobe Portable Document Format
- Description:
- submitted version ("preprint")
- Access level:
- openAccess
- Access rights:
- openly accessible