On radio interference filter measurement
Typ dokumentu
příspěvek z konference - tištěnýAutor
Hoffmann, Karel
Škvor, Zbyněk
Práva
© 2003 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.Metadata
Zobrazit celý záznamAbstrakt
A new measurement method for on site testing of multiport radio interference filters (RIF) on shielded chamber is designed. The method is based on scalar measurement only and makes possible a pessimistic estimate of the filters damping in frequency band from DC-3 GHz. More than 120 dB dynamic of measurement can be expected. At the time being there is no acceptable standard for these multiport measurements.