Seismic resistance of a hybrid shearwall system
Seismic resistance of a hybrid shearwall system
Typ dokumentu
disertační práceAutor
Wirth Ulrich
Vedoucí práce
Křístek Vladimír
Oponent práce
Vítek Jan
Studijní obor
Konstrukce a dopravní stavbyStudijní program
Stavební inženýrství (4)Instituce přidělující hodnost
Fakulta stavebníObhájeno
2011-05-16 00:00:00.0Práva
A university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one’s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://www.cvut.cz/sites/default/files/content/d1dc93cd-5894-4521-b799-c7e715d3c59e/cs/20160901-metodicky-pokyn-c-12009-o-dodrzovani-etickych-principu-pri-priprave-vysokoskolskych.pdfVysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://www.cvut.cz/sites/default/files/content/d1dc93cd-5894-4521-b799-c7e715d3c59e/cs/20160901-metodicky-pokyn-c-12009-o-dodrzovani-etickych-principu-pri-priprave-vysokoskolskych.pdf
Metadata
Zobrazit celý záznamAbstrakt
As part of an experimental research program on the seismic behavior of a new hybrid shearwall building system, with composite concrete-filled steel tubular edge members and typical reinforced concrete (RC) wall panel, test results of one-third scale specimens, covering different interface connections (IFC) between the composite edge members and the reinforced concrete (RC) wall panel, are presented. The specimens have been subjected to cyclic displacement controlled forces acting along the interface between the wall panel and the composite edge member. Considering the load-displacement results, recommendations on the reinforcement at the column-wall interface are presented. As part of an experimental research program on the seismic behavior of a new hybrid shearwall building system, with composite concrete-filled steel tubular edge members and typical reinforced concrete (RC) wall panel, test results of one-third scale specimens, covering different interface connections (IFC) between the composite edge members and the reinforced concrete (RC) wall panel, are presented. The specimens have been subjected to cyclic displacement controlled forces acting along the interface between the wall panel and the composite edge member. Considering the load-displacement results, recommendations on the reinforcement at the column-wall interface are presented.
Zobrazit/ otevřít
Kolekce
- Disertační práce - 11000 [457]
K tomuto záznamu jsou přiřazeny následující licenční soubory: