NUMERICAL SIMULATIONS OF STATIC STRENGTH OF NOVEL DENTAL IMPLANTS
Typ dokumentu
articlePeer-reviewed
publishedVersion
Autor
Řehounek , Luboš
Denk , František
Jíra , Aleš
Práva
Creative Commons Attribution 4.0 International Licensehttp://creativecommons.org/licenses/by/4.0/
openAccess
Metadata
Zobrazit celý záznamAbstrakt
It is important to know the mechanical and micromechanical characteristics of conventional dental implants in order to design and develop novel dental implants and surface treatments that ensure a good biomechanical stability and almost fully replace the biological tissue. A successful integration of the implant depends on its chemical, mechanical and physical properties and the quality of the bone tissue. Considering these facts, we developed two novel variants of dental implant stems with an anti-rotational geometrical solution. On these variants, we have then performed numerical analyses of static strength. Outcomes of simulations vary depending on the type of the implant and load mode.
Kolekce
K tomuto záznamu jsou přiřazeny následující licenční soubory: