Vyhodnocení přesnosti odhadu objemu Langerhansových ostrůvku z mikroskopických obrazů
Accuracy evaluation of Langerhans islet volume estimation from microscopic images
dc.contributor.advisor | Kybic Jan | |
dc.contributor.author | Hlushak Hanna | |
dc.date.accessioned | 2017-02-28T09:02:32Z | |
dc.date.available | 2017-02-28T09:02:32Z | |
dc.date.issued | 2016-05-20 | |
dc.identifier | KOS-597327135305 | |
dc.identifier.uri | http://hdl.handle.net/10467/67590 | |
dc.description.abstract | For successful islet transplantation it is important to input sufficient quantity of islets, hence it is required to know the volume of the transplanted islets. Several methods for estimating the volume from 2D microscopy images are used (the Ricordi table, spherical and ellipsoid models). The aim of this work is to evaluate the accuracy of these methods. With the help of Optical Tomography microscope we made 401 projections of individual islets and created 3D models by image reconstruction. We calculated the individual islet volumes by the isotropic Fakir method and compared them with results from the evaluated 2D methods for 65 real islets and 35 synthetically generated islets. Ellipse fitting method for islet volume estimation performed by plugins of Fiji software was shown to be the most suitable among the evaluated 2D methods. | cze |
dc.description.abstract | For successful islet transplantation it is important to input sufficient quantity of islets, hence it is required to know the volume of the transplanted islets. Several methods for estimating the volume from 2D microscopy images are used (the Ricordi table, spherical and ellipsoid models). The aim of this work is to evaluate the accuracy of these methods. With the help of Optical Tomography microscope we made 401 projections of individual islets and created 3D models by image reconstruction. We calculated the individual islet volumes by the isotropic Fakir method and compared them with results from the evaluated 2D methods for 65 real islets and 35 synthetically generated islets. Ellipse fitting method for islet volume estimation performed by plugins of Fiji software was shown to be the most suitable among the evaluated 2D methods. | eng |
dc.language.iso | ENG | |
dc.publisher | České vysoké učení technické v Praze. Vypočetní a informační centrum. | cze |
dc.publisher | Czech Technical University in Prague. Computing and Information Centre. | eng |
dc.rights | A university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one?s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://knihovny.cvut.cz/vychova/vskp.html | eng |
dc.rights | Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://knihovny.cvut.cz/vychova/vskp.html | cze |
dc.subject | Langerhans islets, volume estimation, OPT microscopy, 2D and 3D methods, synthetic islets. | cze |
dc.subject | Langerhans islets, volume estimation, OPT microscopy, 2D and 3D methods, synthetic islets. | eng |
dc.title | Vyhodnocení přesnosti odhadu objemu Langerhansových ostrůvku z mikroskopických obrazů | cze |
dc.title | Accuracy evaluation of Langerhans islet volume estimation from microscopic images | eng |
dc.type | diplomová práce | cze |
dc.type | master thesis | eng |
dc.date.accepted | 2016-06-22 | |
dc.contributor.referee | Rožánek Martin | |
theses.degree.discipline | Biomedicínské inženýrství | cze |
theses.degree.grantor | katedra biomedicínské techniky | cze |
theses.degree.programme | Biomedicínská a klinická technika (studium v angličtině) | cze |
Soubory tohoto záznamu
Tento záznam se objevuje v následujících kolekcích
-
Diplomové práce - 17110 [1011]