Dozimetrie v rentgenové diagnostice dětských pacientů
Dosimetry in Diagnostic Radiology in Pediatric Patients
Type of document
bakalářská prácebachelor thesis
Author
Kovácsová Zuzana
Supervisor
Novák Leoš
Opponent
Borovičková Simona
Field of study
Dozimetrie a aplikace ionizujícího zářeníStudy program
Aplikace přírodních vědInstitutions assigning rank
katedra dozimetrie a aplikace ionizujícího zářeníDefended
2015-09-01Rights
A university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one?s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://www.cvut.cz/sites/default/files/content/d1dc93cd-5894-4521-b799-c7e715d3c59e/cs/20160901-metodicky-pokyn-c-12009-o-dodrzovani-etickych-principu-pri-priprave-vysokoskolskych.pdfVysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://www.cvut.cz/sites/default/files/content/d1dc93cd-5894-4521-b799-c7e715d3c59e/cs/20160901-metodicky-pokyn-c-12009-o-dodrzovani-etickych-principu-pri-priprave-vysokoskolskych.pdf
Metadata
Show full item recordAbstract
Dětští pacienti jsou radiosenzitivnější než dospělí pacienti a jejich očekávaná doba života je delší. Z těchto důvodu musí být dávky při rentgenových vyšetřeních dětí co nejmenší. Pro nalezení postupů, při kterých jsou dávky zbytečně vysoké, jsou dávky změřené při rentgenových vyšetřeních srovnávány s Diagnostickými referenčními úrovněmi (DRÚ). Předkládaná práce poskytuje přehled veličin, které popisují dávku pacienta a metody jejich měření. Součástí je i shrnutí světových pediatrických DRÚ pro skiagrafická a CT vyšetření. Cílem experimentální části práce bylo měření dávek dle popsaných postupů při běžných skiagrafických a CT vyšetřeních dospělého a pediatrického fantomu. Při skiagrafických vyšetřeních provedených dle klinických protokolů pro danou věkovou kategorii pacienta byly dávky obdržené pediatrickým fantomem simulujícím ročního pacienta výrazně menší, než dávky obdržené fantomem simulujícím dospělého. U CT vyšetření se stejnými expozičními parametry pro všechna měření se dávka se zmenšujícím se objemem fantomu výrazně zvyšovala. Je tedy nutné při vyšetřování dětí dbát na to, aby bylo vyšetření provedeno podle protokolu pro danou věkovou skupinu. Considering the higher radiation sensitivity of paediatric patients and their longer life expectancy, radiation doses in diagnostic radiology examinations of children should be as low as possible. A method of identifying hospitals where doses are exceptionally high is the comparison of measured patient doses with Diagnostic reference levels (DRLs). This thesis provides a summary of quantities describing radiation doses and codes of practise for their measurement. A survey of DRLs for general radiography and computed tomography is also included. The aim of primary research was the assessment of doses in general radiography and computed tomography. It was conducted with phantoms representing an adult and a 1 year old paediatric patient. The results of the general radiography measurements showed that radiation doses received by the paediatric phantom were significantly smaller than those receivedby the adult phantom. The measurements were conducted with settings according to the clinical protocols for each age group. The CT measurements showed growth of radiation dose with the decrease of phantom thickness. Thus it is crucial to examine paediatric patients according to codes of practise for the relevant age group.
Collections
- Bakalářské práce - 14116 [103]
Related items
Showing items related by title, author, creator and subject.
-
Development of Hall sensors for steady state magnetic diagnostic of fusion reactors
Author: Sentkerestiová Jana; Supervisor: Ďuran Ivan; Opponent: Stöckel Jan
(České vysoké učení technické v Praze. Vypočetní a informační centrum., 2014-01-22)Hall sensors development and evaluation for fusion reactors -
Authentication Effectiveness in Vehicle Unified Diagnostic Services
Author: Jakub Weisl; Supervisor: Dostál Jiří; Opponent: Bubílek Aleš
(České vysoké učení technické v Praze. Vypočetní a informační centrum.Czech Technical University in Prague. Computing and Information Centre., 2024-02-09)Tato práce zkoumá časovou efetkivitu a efektivitu přenosu dat v rámci autentizace UDS protokolu. Poukazuje na výhody využití PKI s kryptografickým algoritmem eliptických křivek pro autentizaci. -
Rozšířený dálkově diagnostický systém pro průmyslové odstředivky
Author: Kostadinov Martin; Supervisor: Stefan Libor; Opponent: Legner Miloš
(České vysoké učení technické v Praze. Vypočetní a informační centrum., 2011-10-14)