ČVUT DSpace
  • Search DSpace
  • Čeština
  • Login
  • Čeština
  • Čeština
View Item 
  •   ČVUT DSpace
  • Czech Technical University in Prague
  • Faculty of Electrical Engineering
  • Doctoral Theses - 13000
  • View Item
  • Czech Technical University in Prague
  • Faculty of Electrical Engineering
  • Doctoral Theses - 13000
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Detekce rentgenového záření ve vakuu

Detection of X-ray radiation in vacuum

Type of document
disertační práce
doctoral thesis
Author
Martin Urban
Supervisor
Hudec René
Opponent
Nousek John
Field of study
Radioelektronika
Study program
Elektrotechnika a informatika
Institutions assigning rank
katedra radioelektroniky



Rights
A university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one?s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://knihovny.cvut.cz/vychova/vskp.html
Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://knihovny.cvut.cz/vychova/vskp.html
Metadata
Show full item record
Abstract
Detekce rentgenového záření je klíčová pro výzkum a pochopení mnoha astrofyzikálních jevů, avšak zemská atmosféra značně absorbuje tuto formu záření, což vyžaduje provádění měření na oběžné dráze Země. Tento postup obnáší náročné podmínky, jako je zvýšená radiace, vakuum a extrémní změny teploty. Tato práce se zaměřuje na vliv změny těchto podmínek na přesnost radiačního měření pomocí hybridních pixelových detektorů. Tyto detektory prokázaly svou účinnost během několika vesmírných misí a mají významný aplikační potenciál. Zvláštní důraz je kladen na výzkum vlivu teploty na přesnost měření, v různých měřicích režimech, zejména s cílem určit vliv na přesnost detekce energie dopadajícího rentgenového záření. Výsledky jsou ověřovány a validovány v termovakuové komoře. Tato práce zahrnuje principy měření, popis a charakterizaci zjištěných zkreslení energetických spekter. Dále jsou navrženy dvě unikátní metody kompenzace, které minimalizují popsané teplotní vlivy a umožní tak přesné měření v širokém teplotním rozsahu. V neposlední řade je ověřena i možnost zobecnění a extrapolování navrženého korekčního modelu. Výstupy této studie jsou již využívány při přípravě budoucích vesmírných misí a mají význam pro další vědecké a průmyslové aplikace tohoto typu detektorů. Tato práce poskytuje cenné informace a pomůže zlepšit přesnost měření v oblasti rentgenového záření.
 
The detection of X-rays is crucial to studying and understanding many astrophysical phenomena. However, the Earth's atmosphere significantly attenuates this type of radiation, so measurements must be made in Earth's orbit. This approach involves challenging conditions such as increased radiation, vacuum condition and extreme temperature changes. This thesis focuses on the effect of changing these conditions on the accuracy of radiation measurements using hybrid pixel detectors. These detectors have proven their capability on several space missions and have significant application potential. Particular emphasis is placed on investigating the effect of temperature on measurement accuracy in different measurement modes, especially the impact on the detection of the energy of the incident X-ray radiation. The results are verified and validated in a thermal vacuum chamber. This thesis addresses the measurement principles, description and characterisation of the identified distortions in the energy spectra. In addition, two unique compensation methods are proposed that minimise the described temperature effects and thus provide accurate measurements over a~wide temperature range. Finally, the possibility of generalising and extrapolating the proposed correction model is presented and verified. The results of this research are relevant to further scientific and industrial applications of this type of detector and are already being used in the preparation of future space missions. This~work provides valuable information and will help to improve the accuracy of X-ray measurements.
 
URI
http://hdl.handle.net/10467/108098
View/Open
PLNY_TEXT (61.05Mb)
Collections
  • Disertační práce - 13000 [748]

České vysoké učení technické v Praze copyright © 2016 

DSpace software copyright © 2002-2016  Duraspace

Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Useful links

CTU in PragueCentral library of CTUAbout CTU Digital LibraryResourcesStudy and library skillsResearch support

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

České vysoké učení technické v Praze copyright © 2016 

DSpace software copyright © 2002-2016  Duraspace

Contact Us | Send Feedback
Theme by 
@mire NV