EVALUATION OF HOPKINSON BAR EXPERIMENTS USING MULTIPLE DIGITAL IMAGE CORRELATION SOFTWARE TOOLS
dc.contributor.author | Adorna, Marcel | |
dc.contributor.author | Brodner, Stefan | |
dc.contributor.author | Falta, Jan | |
dc.contributor.author | Zlámal, Petr | |
dc.contributor.author | Fíla, Tomáš | |
dc.date.accessioned | 2023-01-18T15:26:50Z | |
dc.date.available | 2023-01-18T15:26:50Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Acta Polytechnica. 2019, vol. 25, no. 0, p. 1-5. | |
dc.identifier.issn | 1210-2709 (print) | |
dc.identifier.issn | 1805-2363 (online) | |
dc.identifier.uri | http://hdl.handle.net/10467/106135 | |
dc.description.abstract | Three different tools for Digital Image Correlation (DIC) were used for evaluation of dynamic experiments performed using custom Open Hopkinson Pressure Bar (OHPB) apparatus. High strain-rate measurements were performed on specimens of advanced cellular materials with predefined structure and negative Poisson’s ratio. Low impedance polymethyl methacrylate (PMMA) bars instrumented with foil strain-gauges were used for dynamic loading of the specimens. Experiments were observed using a pair of high-speed cameras for imaging of loading process in sufficient quality. Custom developed evaluation DIC tool implemented in Matlab, open-source Matlab tool (NCorr) and commercial DIC software (ISTRA 4D) were all used for evaluation of image sequences recorded by high-speed cameras. Comparison of results obtained using all three different DIC tools and results of complementary strain-gauge measurement are shown in this paper. Verification of reliability of custom made DIC software tool is presented. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | České vysoké učení technické v Praze | cs |
dc.publisher | Czech Technical University in Prague | en |
dc.relation.ispartofseries | Acta Polytechnica | |
dc.relation.uri | https://ojs.cvut.cz/ojs/index.php/APP/article/view/6010 | |
dc.rights | Creative Commons Attribution 4.0 International License | en |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.title | EVALUATION OF HOPKINSON BAR EXPERIMENTS USING MULTIPLE DIGITAL IMAGE CORRELATION SOFTWARE TOOLS | |
dc.type | article | en |
dc.date.updated | 2023-01-18T15:26:50Z | |
dc.identifier.doi | 10.14311/APP.2019.25.0001 | |
dc.rights.access | openAccess | |
dc.type.status | Peer-reviewed | |
dc.type.version | publishedVersion |