ČVUT DSpace
  • Search DSpace
  • Čeština
  • Login
  • Čeština
  • Čeština
View Item 
  •   ČVUT DSpace
  • Czech Technical University in Prague
  • Faculty of Mechanical Engineering
  • Department of Environmental Engineering
  • Master Theses - 12116
  • View Item
  • Czech Technical University in Prague
  • Faculty of Mechanical Engineering
  • Department of Environmental Engineering
  • Master Theses - 12116
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Využití čističek vzduchu

Use of Air Purifiers

Type of document
diplomová práce
master thesis
Author
Mizera Vojtěch
Supervisor
Vybíral Pavel
Opponent
Šťávová Petra
Field of study
bez oboru
Study program
Inteligentní budovy
Institutions assigning rank
ústav techniky prostředí
Defended
2017-09-05



Rights
A university thesis is a work protected by the Copyright Act. Extracts, copies and transcripts of the thesis are allowed for personal use only and at one?s own expense. The use of thesis should be in compliance with the Copyright Act http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf and the citation ethics http://knihovny.cvut.cz/vychova/vskp.html
Vysokoškolská závěrečná práce je dílo chráněné autorským zákonem. Je možné pořizovat z něj na své náklady a pro svoji osobní potřebu výpisy, opisy a rozmnoženiny. Jeho využití musí být v souladu s autorským zákonem http://www.mkcr.cz/assets/autorske-pravo/01-3982006.pdf a citační etikou http://knihovny.cvut.cz/vychova/vskp.html
Metadata
Show full item record
Abstract
Práce informuje o výsledcích měření domácích čističek vzduchu Daikin MC 707 VM a Ionic Care Triton X6. Byly posouzeny jednotlivé výkonnostní stupně obou čističek vzduchu. Experiment proběhl v laboratorním prostředí a v reálném prostředí. Při experimentu v reálném prostředí byla monitorována koncentrace CO2. Množství částic v prostoru bylo měřeno analyzátorem Grimm 1.109. Výsledky všech měření byly vyneseny do příslušných grafů.
 
The diploma thesis informs about the results of the Daikin MC 707 VM and Ionic Care Triton X6 domextic air purifiers. The individual performance levels of both air purifiers have been assessed. The experiment was conducted in a laboratory environment and in real environmnent. In the real environment, the concetration of CO2 was monitored. The amount of particicles in the space was measured by the Grimm 1.109 analyzer. The results of all measurements were plotted in the graphs.
 
URI
http://hdl.handle.net/10467/73345
View/Open
PLNY_TEXT (3.043Mb)
PRILOHA (41.57Mb)
POSUDEK (196.4Kb)
POSUDEK (366.9Kb)
Collections
  • Diplomové práce - 12116 [204]

České vysoké učení technické v Praze copyright © 2016 

DSpace software copyright © 2002-2016  Duraspace

Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Useful links

CTU in PragueCentral library of CTUAbout CTU Digital LibraryResourcesStudy and library skillsResearch support

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

České vysoké učení technické v Praze copyright © 2016 

DSpace software copyright © 2002-2016  Duraspace

Contact Us | Send Feedback
Theme by 
@mire NV