INSTRUMENTATION OF FOUR-POINT BENDING TEST DURING 4D COMPUTED TOMOGRAPHY
Supervisors
Reviewers
Editors
Other contributors
Journal Title
Journal ISSN
Volume Title
Publisher
České vysoké učení technické v Praze
Czech Technical University in Prague
Czech Technical University in Prague
Date
Abstract
High-resolution time-lapse micro-focus X-ray computed tomography is an effective method for investigation of deformation processes on volumetric basis including fracture propagation characteristics of non-homogeneous materials subjected to mechanical loading. This experimental method requires implementation of specifically designed loading devices to X-ray imaging setups. In case of bending tests, our background research showed that no commercial solution allowing for reliable investigation of so called fracture process zone in quasi-brittle materials is currently available. Thus, this paper is focused on description of recently developed in-situ four-point bending loading device and its instrumentation for testing of quasi-brittle materials. Proof of concept together with the pilot experiments were successfully performed in a CT scanner TORATOM. Based on results of the pilot experiments, we demonstrate that crack development and propagation in a quasi-brittle material can be successfully observed in 3D using high resolution 4D micro-CT under loading.
Description
Keywords
Citation
Acta Polytechnica. 2018, vol. 18, no. 0, p. 20-23.