Disinfection performance of an ultraviolet lamp: a CFD investigation

dc.contributor.author Bui, Cuong Mai
dc.contributor.author Phan, Nguyen Duy Minh
dc.contributor.author Tran, Ngo Quoc Huy
dc.contributor.author Doan, Le Anh
dc.contributor.author Vo, Quang Truong
dc.contributor.author Tran, Duy Chung
dc.contributor.author Nguyen, Thi Thanh Vi
dc.contributor.author Nguyen, Duc Long
dc.contributor.author Huynh, Van Sanh
dc.contributor.author Ho, Tran Anh Ngoc
dc.date.accessioned 2022-12-21T09:32:56Z
dc.date.available 2022-12-21T09:32:56Z
dc.date.issued 2022
dc.date.updated 2022-12-21T09:32:57Z
dc.description.abstract Ultraviolet (UV)-based devices have shown their effectiveness on various germicidal purposes. To serve their design optimisation, the disinfection effectiveness of a vertically cylindrical UV lamp, whose wattage ranges from P = 30 − 100 W, is numerically investigated in this work. The UV radiation is solved by the Finite Volume Method together with the Discrete Ordinates model. Various results for the UV intensity and its bactericidal effects against several popular virus types, i.e., Corona-SARS, Herpes (type 2), and HIV, are reported and analysed in detail. Results show that the UV irradiance is greatly dependent on the lamp power. Additionally, it is indicated that the higher the lamp wattage employed, the larger the bactericidal rate is observed, resulting in the greater effectiveness of the UV disinfection process. Nevertheless, the wattage of P ≤ 100W is determined to be insufficient for an effective disinfection performance in a whole room; higher values of power must hence be considered in case intensive sterilization is required. Furthermore, the germicidal effect gets reduced with the viruses less sensitive to UV rays, e.g, the bactericidal rate against the HIV virus is only ∼8.98% at the surrounding walls. en
dc.format.mimetype application/pdf
dc.identifier.citation Acta Polytechnica. 2022, vol. 62, no. 4, p. 418-426.
dc.identifier.doi 10.14311/AP.2022.62.0418
dc.identifier.issn 1210-2709 (print)
dc.identifier.issn 1805-2363 (online)
dc.identifier.uri http://hdl.handle.net/10467/105444
dc.language.iso eng
dc.publisher České vysoké učení technické v Praze cs
dc.publisher Czech Technical University in Prague en
dc.relation.ispartofseries Acta Polytechnica
dc.relation.uri https://ojs.cvut.cz/ojs/index.php/ap/article/view/7627
dc.rights Creative Commons Attribution 4.0 International License en
dc.rights.access openAccess
dc.rights.uri http://creativecommons.org/licenses/by/4.0/
dc.title Disinfection performance of an ultraviolet lamp: a CFD investigation
dc.type article en
dc.type.status Peer-reviewed
dc.type.version publishedVersion
dspace.entity.type Publication

Files

Original bundle

Now showing 1 - 1 of 1
Name:
6311d29494473.pdf
Size:
4.03 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
License.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: