HYBRID SHEARWALL SYSTEM — SHEAR STRENGTH AT THE INTERFACE CONNECTION

Supervisors

Reviewers

Editors

Other contributors

Journal Title

Journal ISSN

Volume Title

Publisher

České vysoké učení technické v Praze
Czech Technical University in Prague

Date

Research Projects

Organizational Units

Journal Issue

Abstract

Based on a series of alternating, displacement-controlled load tests on ten one-third scale models, to study the behaviour of the interface of a hybrid shear wall system, it was proved that the concept of hybrid construction in earthquake prone regions is feasible. The hybrid shear-wall system consists of typical reinforced concrete shear walls with composite edge members or flanges. Ten different anchorage bar arrangements were developed and tested to evaluate the column-shearwall interface behaviour under cyclic shear forces acting along the interface between column and wall panel. Finite element models of the test specimens were developed that were capable of capturing the integrated concrete and reinforcing steel behaviour in the wall panels. Special models were  developed to capture the interface behaviour between the edge columns and the shear wall. A comparison between the experimental results and the numerical results shows excellent agreement, and clearly supports the validity of the model developed for predicting the non-linear response of the hybrid wall system under various load conditions.

Description

Keywords

Citation

Acta Polytechnica. 2013, vol. 53, no. 6.

Endorsement

Review

Supplemented By

Referenced By